<D3. Constructing a Field Wireless System>
D3-60
IM 01W02D01-01EN
DEV_STATUS data conguration and content
Modbus
address
Name Data format Details
n Data status Unsigned16 Usually 0x0080: Normal
n+1
DEV_STATUS
Unsigned16
Status of the eld wireless device (0: connected, 2: not
connected)
n+2 Integer16
Battery life (0>: days, <0: hours, 0x7FFF: external
power source)
n+3 ~ n+8 Unsigned16 Usually 0 (Reserved bits)
Only (n+1) and (n+2) are used
For GW_STATUS, see Section F2.1 Status Information.
For details about other parameters, see the user manual of the relevant model.
For Normal Mapping
The status and value of the parameters which send to a host system can be combined and
mapped. The rst time the [Input Registers] tab is opened at the [Modbus Settings] tab, GW_
STATUS is already positioned at the top (0 to 8). The allocation position of GW_STATUS can be
changed by dragging it in the [Input Registers] list.
Figure D3-61 shows an example of parameters mapped to the input registers.