Yokogawa FieldMate User Manual

Browse online or download User Manual for Sensors Yokogawa FieldMate. Yokogawa FieldMate User Manual [en]

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Synchronization Tool

User’sManualPRM Synchronization ToolIM 01R01A20-01EIM 01R01A20-01E8th Edition

Page 2 - CONTENTS

<3 PRM Synchronization Tool start>3-1IM 01R01A20-01E3 PRM Synchronization Tool startThis chapter provides detailed steps on how to use the

Page 3

<3 PRM Synchronization Tool start>3-2IM 01R01A20-01E3-1 Restoring device information from PRM to FieldMateSelect the Restore activity to t

Page 4 - IMPORTANT

<3 PRM Synchronization Tool start>3-3IM 01R01A20-01E7. SelectaPRMDeviceNavigatoroption:• [PlantView]todisplayPlantviewinther

Page 5 - 1 Overview

<3 PRM Synchronization Tool start>3-4IM 01R01A20-01E8. Intherightpane,clickthecheckboxescorrespondingtothedevicesyouwanttoi

Page 6 -  Data for Tool

<3 PRM Synchronization Tool start>3-5IM 01R01A20-01E Handling overwrite messagesDuringtheRestoreactivity,theOverwritingMessagedial

Page 7 - 2 Operation Preparation

<3 PRM Synchronization Tool start>3-6IM 01R01A20-01E3-2 Backing up device information from FieldMate to PRMAfter performing device tuning

Page 8 - Fordetails,pleasesee:

<3 PRM Synchronization Tool start>3-7IM 01R01A20-01E7. SelectaFieldMateDeviceNavigatoroption:• [All]todisplayallFieldMatedevice

Page 9

<3 PRM Synchronization Tool start>3-8IM 01R01A20-01E9. Clickthe[DeleteselecteddevicesfromFieldMateafterBackupActivity]checkbox

Page 10 - 8th Edition : May 31, 2013-00

<3 PRM Synchronization Tool start>3-9IM 01R01A20-01E 8th Edition : May 31, 2013-003-3 Synchronizing device information between PRM and Fie

Page 11 - FieldMate

<3 PRM Synchronization Tool start>3-10IM 01R01A20-01E 8th Edition : May 31, 2013-00030306E.aiFigure3-6 PRM Synchronization Tool window - S

Page 12 - SEE ALSO

Toc-1IM 01R01A20-01EPRM Synchronization ToolCONTENTSIM 01R01A20-01E 8th Edition8th Edition : May 31, 2013-00A Symbol Marks in the User’s Manual ...

Page 13

<3 PRM Synchronization Tool start>3-11IM 01R01A20-01E 8th Edition : May 31, 2013-00TIPYoucanalsostoptheactivityatanypointintime.

Page 14

<3 PRM Synchronization Tool start>3-12IM 01R01A20-01E 8th Edition : May 31, 2013-003-4 Performingadvancedcongurationsandsearching dev

Page 15 - FieldMate to PRM

<3 PRM Synchronization Tool start>3-13IM 01R01A20-01E 8th Edition : May 31, 2013-00 HistoryHistorymessagescanbeincludedinthedatatr

Page 16

<3 PRM Synchronization Tool start>3-14IM 01R01A20-01E 8th Edition : May 31, 2013-00 MemoYoucanincludeamaximumof1000memosduringdat

Page 17

<3 PRM Synchronization Tool start>3-15IM 01R01A20-01E 8th Edition : May 31, 2013-00 Parameter setsYoucanconguretheparametersetfor

Page 18 - PRM and FieldMate

<3 PRM Synchronization Tool start>3-16IM 01R01A20-01E 8th Edition : May 31, 2013-004. Click[OK]toapplyandsavethesettings.• Click[

Page 19

<3 PRM Synchronization Tool start>3-17IM 01R01A20-01E 8th Edition : May 31, 2013-00 Searching for a deviceTheDeviceNavigatorprovidesa

Page 20 -  Handlingconictmessages

<4 Device Tag Extension Mode>4-1IM 01R01A20-01E4 Device Tag Extension Mode Outline of PRM/FieldMate synchronization compatibilitiesDevic

Page 21

<4 Device Tag Extension Mode>4-2IM 01R01A20-01E Synchronizing Devices with HART Device Tag Display FormatThesameDeviceTagExtensionMo

Page 22 -  History

<4 Device Tag Extension Mode>4-3IM 01R01A20-01E Synchronizing Devices in STARDOM Upstream ProjectTIPThe followings describes sample case

Page 23 -  Documents

Toc-2IM 01R01A20-01E 8th Edition : May 31, 2013-004 Device Tag Extension Mode ... 4-

Page 24 -  Parameter sets

App.-1IM 01R01A20-01EAppendixReferences1. FieldMate Versatile Device Management Wizard (IM 01R01A01-01E).8th Edition : May 31, 2013-00

Page 25 -  DTM data

IM 01R01A20-01ERevision InformationTitle : FieldMate:PRMSynchronizationToolManualNo. : IM01R01A20-01ERevision No. Revised Date Major Chan

Page 26 -  Searching for a device

<A Symbol Marks in the User’s Manual>A-1IM 01R01A20-01EA Symbol Marks in the User’s ManualThesymbolmarksappearingintheuser’smanual

Page 27 - 4 Device Tag Extension Mode

<1 Overview>1-1IM 01R01A20-01E1 OverviewPRM Synchronization Tool realizes device information exchange between FieldMate and Plant Resource

Page 28

<1 Overview>1-2IM 01R01A20-01E Device for Tool Supported communication protocolFOUNDATIONeldbusHARTBRAIN Devices Devicesregistered

Page 29

<2 Operation Preparation>2-1IM 01R01A20-01E2 Operation PreparationThis chapter describes the operation preparation before starting PRM Sy

Page 30 - Appendix

<2 Operation Preparation>2-2IM 01R01A20-01ENOTEPRMSynchronizationToolisincludedintheFieldMateR1.03/R2.01orlater.Itwillbeinsta

Page 31 - Revision Information

<2 Operation Preparation>2-3IM 01R01A20-01E DenePRMServertoconnecttoUseFieldMate’sPRMSetupTooltospecifythePRMServerwhere

Comments to this Manuals

No comments