Summary of Contents

Page 1 - Power and Energy Meter

User’sManualIM 77C01E01-01EModel PR300Power and Energy MeterIM 77C01E01-01E4th Edition

Page 2 - Introduction

1-3IM 77C01E01-01E112345AIInstallation and Wiring1.2 Installation with the DIN 96-square InstrumentSizeExternal DimensionsMounting bracket(2 places)10

Page 3 - ■Regarding This User’s Manual

1-4IM 77C01E01-01E1.2 Installation with the DIN 96-square Instrument Size● Do not install the PR300 in the following types of environments, as they ma

Page 4 - Checking the Package

1-5IM 77C01E01-01E112345AIInstallation and Wiring1.3 WiringWARNING● As there is a danger of electric shock, turn off the power supply and check that t

Page 5 - Checking the Accessories

1-6IM 77C01E01-01E1.3 WiringSingle-phase two-wire system (voltage input, current input, power supply)12 345678910111213141516171819202122232425abcdefL

Page 6 - Contents

1-7IM 77C01E01-01E112345AIInstallation and Wiring1.3 WiringThree-phase four-wire system (voltage input, current input, power supply)123456789101112131

Page 7 - Chapter 5 Troubleshooting

1-8IM 77C01E01-01E1.3 WiringOther Wiring12345678910111213141516171819202122232425abcdefColorDescriptionColorDescriptionLink LEDOffStoppedActive LEDOff

Page 8

1-9IM 77C01E01-01E112345AIInstallation and Wiring1.4 Attaching the Dust Cover and Terminal CoverWARNINGAs there is a danger of electric shock, do not

Page 9

Preparations before Starting Measurement (Set up the PR300 First)2-1IM 77C01E01-01E12345AIChapter 2 Preparations before Starting Measurement (Set up t

Page 10 - Panel Cutout Dimensions

2-2IM 77C01E01-01E2.2 Setting the Phase and Wire SystemThis section explains how to set the phase and wire system by taking as an example the case whe

Page 11 - Mounting Method

Preparations before Starting Measurement (Set up the PR300 First)2-3IM 77C01E01-01E12345AI2.2 Setting the Phase and Wire SystemMeasured Value screenSt

Page 12 - 1.3 Wiring

iIM 77C01E01-01EIntroductionThank you for purchasing the PR300 Power and Energy Meter.This manual provides information about the procedure for install

Page 13

2-4IM 77C01E01-01E2.3 Setting the Voltage RangeThis section explains how to set the voltage range by taking as an example the case when the voltageran

Page 14 - Installation and Wiring

Preparations before Starting Measurement (Set up the PR300 First)2-5IM 77C01E01-01E12345AI2.3 Setting the Voltage RangeHold down for at le

Page 15 - Other Wiring

Parameter Setting Operations3-1IM 77C01E01-01E12345AIChapter 3 Parameter Setting Operations3.1 Basic Parameter Setting OperationsNOTESet parameters on

Page 16 - IM 77C01E01-01E

3-2IM 77C01E01-01E3.2 Setting the VT and CT RatiosSetting the VT RatioThis section explains how to set the VT ratio by taking as an example the case w

Page 17 - Description

Parameter Setting Operations3-3IM 77C01E01-01E12345AI3.2 Setting the VT and CT RatiosSetting the CT RatioThis section explains how to set the CT ratio

Page 18 - Operation

3-4IM 77C01E01-01E3.3 Setting the Integrated Low-cut PowerThis section explains how to set the integrated low-cut power by taking as an example the ca

Page 19 - Setting completed

Parameter Setting Operations3-5IM 77C01E01-01E12345AI3.3 Setting the Integrated Low-cut PowerParameter Setting Types and RangesParameter Symbol Parame

Page 20 - 2.3 Setting the Voltage Range

3-6IM 77C01E01-01E3.4 Setting RS-485 Communication ConditionsThis section explains how to set RS-485 communication conditions by taking as an example

Page 21

Parameter Setting Operations3-7IM 77C01E01-01E12345AI3.4 Setting RS-485 Communication ConditionsNOTE● The Modbus/TCP protocol can only be selected for

Page 22 - Key operations used

3-8IM 77C01E01-01EFor the PR300 with Ethernet communication function only3.5 Setting Ethernet Communication ConditionsThis section explains how to set

Page 23 - Setting the VT Ratio

iiIM 77C01E01-01ENotices Regarding This User’s Manual• This manual should be passed on to the end user. Keep the manual in a safe place.• Read this ma

Page 24 - Setting the CT Ratio

Parameter Setting Operations3-9IM 77C01E01-01E12345AI3.5 Setting Ethernet Communication ConditionsSet the settings of parameter to ON and

Page 25

3-10IM 77C01E01-01EFor the PR300 with pulse output function only3.6 Setting Pulse Output ConditionsThis section explains how to set pulse output condi

Page 26

Parameter Setting Operations3-11IM 77C01E01-01E12345AI3.6 Setting Pulse Output ConditionsNOTEIf the pulse unit and ON pulse width do not satisfy the f

Page 27

3-12IM 77C01E01-01EFor the PR300 with analog output function only3.7 Setting Analog Output ConditionsThis section explains how to set analog output co

Page 28 - (*2)(*3)

Parameter Setting Operations3-13IM 77C01E01-01E12345AI3.7 Setting Analog Output ConditionsTo change the upper limit of scaling, set a new limit usingt

Page 29

3-14IM 77C01E01-01EFor the PR300 with demand measurement function only3.8 Setting Demand Measurement ConditionsThis section explains how to set demand

Page 30

Parameter Setting Operations3-15IM 77C01E01-01E12345AI3.8 Setting Demand Measurement ConditionsDemand Alarm Point screen1112141513Demand Alarm Release

Page 31

3-16IM 77C01E01-01E3.9 Setting the Measured Value Display PatternThis section explains how to set the measured value display pattern by taking as an e

Page 32 - Primary rated power  1.2  2

Parameter Setting Operations3-17IM 77C01E01-01E12345AI3.9 Setting the Measured Value Display PatternDisplay Pattern-1 Upper Display screenDisplay Patt

Page 33

3-18IM 77C01E01-01E3.9 Setting the Measured Value Display PatternParameter Setting Types and Ranges (Continued)Voltage-2Voltage-3Current(phase switch

Page 34

iiiIM 77C01E01-01E Force Majeure• Yokogawa does not make any warranties regarding the product except those mentioned in theWARRANTY that is provided s

Page 35

Parameter Setting Operations3-19IM 77C01E01-01E12345AI3.10 Setting the “Indicator-out” Mode and LockingParametersSetting the Indicator-out ModeThis se

Page 36 - Point screen

3-20IM 77C01E01-01E3.10 Setting the “Indicator-out” Mode and Locking ParametersParameter Setting Types and RangesDisplay setting menuIndicator-out mod

Page 37

Operation for Display of Measurement Items and Measurement Method4-1IM 77C01E01-01E12345AChapter 4 Operation for Display of Measurement Items and Meas

Page 38 - Refer to steps

4-2IM 77C01E01-01E4.2 Switching Display PatternAccording to Display patterns-1 to 8, the PR300 can change the measurement items to be assigned tothe u

Page 39

Operation for Display of Measurement Items and Measurement Method4-3IM 77C01E01-01E12345A4.3 Displaying Measured, Instantaneous, andMaximum/Minimum Va

Page 40 - Parameters

4-4IM 77C01E01-01E4.3 Displaying Measured, Instantaneous, and Maximum/Minimum ValuesExample Display and Measuring Ranges of VoltageVoltage-2Voltage-1V

Page 41

Operation for Display of Measurement Items and Measurement Method4-5IM 77C01E01-01E12345A4.3 Displaying Measured, Instantaneous, and Maximum/Minimum V

Page 42 - 4.1 Measurement Items

4-6IM 77C01E01-01E4.4 Phase Switching for Voltage and CurrentUsing an operation key ( ) of the PR300, the user can switch the phase of voltage, curren

Page 43 - 4.2 Switching Display Pattern

Operation for Display of Measurement Items and Measurement Method4-7IM 77C01E01-01E12345A4.5 Displaying Energy ValuesThis section explains the measuri

Page 44 - Maximum/Minimum Values

4-8IM 77C01E01-01E4.5 Displaying Energy ValuesOperation for Energy Value DisplayFor all measurement ranges of active energy, regenerative energy, LEAD

Page 45

ivIM 77C01E01-01EChecking the AccessoriesModel PR300Power and Energy Meter<Initial Setup Operations>Model PR300Power and Energy Meter<Install

Page 46 - Frequency

Operation for Display of Measurement Items and Measurement Method4-9IM 77C01E01-01E12345A4.5 Displaying Energy ValuesOptional Integrating FunctionThe

Page 47 - Current-2 or Current-3

4-10IM 77C01E01-01E4.6 Resetting Measured ValuesResetting Maximum and Minimum ValuesOperationOperationSimultaneously hold down and

Page 48 - 4.5 Displaying Energy Values

Operation for Display of Measurement Items and Measurement Method4-11IM 77C01E01-01E12345A4.6 Resetting Measured ValuesCanceling Reset Item Selection

Page 49 - Electric energy

4-12IM 77C01E01-01E4.7 Demand Measurement (Optional MeasuringFunction)The PR300 (with the demand measuring function) can measure the average power or

Page 50 - Optional Integrating Function

Operation for Display of Measurement Items and Measurement Method4-13IM 77C01E01-01E12345A4.7 Demand Measurement (Optional Measuring Function)Operatio

Page 51 - 4.6 Resetting Measured Values

4-14IM 77C01E01-01E4.7 Demand Measurement (Optional Measuring Function)Demand AlarmDemand alarm outputFunction: When the set demand alarm point is exc

Page 52 - Reset Items and Details

Troubleshooting5-1IM 77C01E01-01E12345A5.1 Error Display and Recommended ResponseFailure at the Time of Turning on the Power and during OperationRecom

Page 53 - Function)

5-2IM 77C01E01-01E5.2 MaintenanceCleaningThe front panel and operation keys should be gently wiped with a dry cloth.NOTEDo not use alcohol, benzine, o

Page 54

AppendixA-1IM 77C01E01-01E12345AAppendixAppendix 1 Specifications of PR300Measuring FunctionActive energy (regenerative energy)The active power up to

Page 55 - Example Demand Measurement

A-2IM 77C01E01-01EAppendix 1 Specifications of PR300*: The setting of the voltage range can be changed.**: The primary voltage of VT.Power Items an

Page 56 - Errors during Operation

TOC-1IM 77C01E01-01E112345AIModel PR300 Power and Energy MeterIM 77C01E01-01EContentsIntroduction...

Page 57 - 5.2 Maintenance

AppendixA-3IM 77C01E01-01E12345AAppendix 1 Specifications of PR300Digital Input SpecificationsIt is used for control signals for optional integrati

Page 58 - Measuring Function

A-4IM 77C01E01-01EAppendix 1 Specifications of PR300Demand Alarm Output Specifications (optional measuring function)When the demand measurement val

Page 59 - Input Specifications

AppendixA-5IM 77C01E01-01E12345AAppendix 1 Specifications of PR300Example of connection diagram(SG)(SG)(SG)(Bⴙ)(Aⴚ)(Bⴙ)(Aⴚ)(FG)TerminatorRS-485RS-4

Page 60 - Digital Input Specifications

A-6IM 77C01E01-01EAppendix 1 Specifications of PR300Modbus/TCP functionCode03060816FunctionReads data from multiple D registersWrites data into D r

Page 61 - Communication Specifications

AppendixA-7IM 77C01E01-01E12345AAppendix 1 Specifications of PR300Insulation resistance Between each of the voltage input, current input, power, gr

Page 62 - Appendix

A-8IM 77C01E01-01EAppendix 1 Specifications of PR300Environmental ConditionsNormal operating conditionsWarm-up time At least 30 minutesAmbient temp

Page 63 - Standard Performance

AppendixA-9IM 77C01E01-01E12345AAppendix 2 System ResetThere are two methods of performing system reset:• Turn off the power of the PR300 and then tur

Page 64

A-10IM 77C01E01-01EAppendix 3 Parameter MapSome of the following parameters cannot be displayed due to the specifications of the PR300.To move to the

Page 65 - Mounting and Shape

AppendixA-11IM 77C01E01-01E12345AAppendix 3 Parameter Setting Procedure15-16-17-18-19-19-29-39-49-59-79-69-89-99-109-119-129-139-149-159-169-179-189

Page 66 - Appendix 2 System Reset

A-12IM 77C01E01-01EAppendix 4 Parameter ListParameterSymbolDisplay OrderParameter Name MEMOSetting TypeSetting Range (Details)Initial Value(Factory-se

Page 67 - Appendix 3 Parameter Map

TOC-2IM 77C01E01-01EChapter 4Operation for Display of Measurement Items and Measurement Method4.1 Measurement Items ...

Page 68 - Parameter screen

AppendixA-13IM 77C01E01-01E12345AAppendix 4 Parameter List5-85-95-105-115-125-135-1466-16-26-377-17-27-388-100000502Menu to shift to the parameters

Page 69 - Appendix 4 Parameter List

A-14IM 77C01E01-01EAppendix 4 Parameter List8-28-38-48-599-19-29-39-49-59-69-79-89-99-109-119-129-139-149-159-169-179-181001Current(phase switch in

Page 70 - Appendix 4 Parameter List

AppendixA-15IM 77C01E01-01E12345AAppendix 4 Parameter List9-199-209-219-229-239-249-259-269-27Voltage(phase switch indication)FrequencyCurrent(phase

Page 71 - Appendix 4 Parameter List

A-16IM 77C01E01-01EAppendix 5 Alphanumeric Characters Table for7-segment LEDThe PR300 uses a 7-segment LED as its display. It displays alphanumeric ch

Page 72 - Voltage Range

Index-1IM 77C01E01-01E12345AIIndexIndexIndexAAnalog output conditions setting ... 3-12CComponent names and functio

Page 73 - 7-segment LED

Index-2IM 77C01E01-01EWWiring diagramSingle-phase two-wire system ... 1-6Single-phase three-wire system ...

Page 74

YOKOGAWA ELECTRIC CORPORATIONHeadquarters2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JAPANBranch Sales OfficesNagoya, Osaka, Hiroshima, Fukuoka, S

Page 75

1-1IM 77C01E01-01E112345AIInstallation and WiringChapter 1 Installation and Wiring1.1 Installation with the ANSI 4-inch Round Form orJIS 110-square In

Page 76 - May '08

1-2IM 77C01E01-01E1.1 Installation with the ANSI 4-inch Round Form or JIS 110-square Instrument Size● Do not install the PR300 in the following types