<9. General Specications>
9-5
IM 01C25F01-01E
9.2 Model and Sufx Codes
Model Sufx Codes Description
EJX510A
EJX530A
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
Absolute pressure transmitter
Gauge pressure transmitter
Output
signal
-D . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . .
-J . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC Output with digital communication (BRAIN protocol)
4 to 20 mA DC Output with digital communication (HART protocol)
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
Digital communication (FOUNDATION Fieldbus protocol,
refer to IM 01C25T02-01E)
Digital communication (PROFIBUS PA protocol,
refer to IM 01C25T04-01EN)
Measurement
span (capsule)
A. . . . . . . . . . . . . . . . . . .
B. . . . . . . . . . . . . . . . . . .
C. . . . . . . . . . . . . . . . . . .
D. . . . . . . . . . . . . . . . . . .
8 to 200 kPa (1.16 to 29 psi)
0.04 to 2 MPa (5.8 to 290 psi)
0.2 to 10 MPa (29 to 1450 psi)
1 to 50 MPa (145 to 7200 psi)
Wetted parts
material
S . . . . . . . . . . . . . . . . . .
H. . . . . . . . . . . . . . . . . .
Process connection Diaphragm
316L SST Hastelloy C-276
*1
Hastelloy C-276
*1
Hastelloy C-276
*1
Process
connections
4 . . . . . . . . . . . . . . . .
7 . . . . . . . . . . . . . . . .
8 . . . . . . . . . . . . . . . .
9 . . . . . . . . . . . . . . . .
1/2 NPT female
1/2 NPT male
G1/2 DIN 16 288 male
*2
M21.5 DIN 16 288 male
*2
N. . . . . . . . . . . . . . Always N
-0 . . . . . . . . . . .
Always 0
Amplier housing 1 . . . . . . . . . .
2 . . . . . . . . . .
3 . . . . . . . . . .
Cast aluminum alloy
ASTM CF-8M Stainless steel
*4
Cast aluminum alloy with corrosion resistance properties
Electrical connection
0 . . . . . . . . .
2 . . . . . . . . .
4 . . . . . . . . .
5 . . . . . . . . .
7 . . . . . . . . .
9 . . . . . . . . .
A. . . . . . . . .
C. . . . . . . . .
D. . . . . . . . .
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs
M20 female, two electrical connections without blind plugs
G1/2 female, two electrical connections with a blind plug
1/2 NPT female, two electrical connections with a blind plug
M20 female, two electrical connections with a blind plug
G1/2 female, two electrical connections with a 316SST blind plug
1/2 NPT female, two electrical connections with a 316SST blind plug
M20 female, two electrical connections with a 316SST blind plug
Integral indicator
D. . . . . . .
E . . . . . . .
N. . . . . . .
Digital indicator
*5
Digital indicator with the range setting switch
*3
None
Mounting bracket
F . . . . .
L . . . . .
N. . . . .
304 SST 2-inch pipe mounting
316 SST 2-inch pipe mounting
None
Optional codes
/ Optional specication
The “►” marks indicate the most typical selection for each specication. Example: EJX530A-DAS4N-012NN/.
*1: Hastelloy C-276 or ASTM N10276.
*2: Not applicable for combination of capsule code D and wetted parts material code H.
*3: Not applicable for output signal code F.
*4: Not applicable for electrical connection code 0, 5, 7 and 9.
*5: Not applicable for output signal code G.