Yokogawa EJA110E User Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
<9. General Specications>
9-3
IM 01C25B01-01E
Normal Operating Condition
(Selected features may affect limits.)
Ambient Temperature Limits
–40 to 85°C (–40 to 185°F)
–30 to 80°C (–22 to 176°F) with LCD display
–25 to 80°C (–40 to 176°F) for EJ120
Process Temperature Limits
–40 to 12C (–40 to 248°F)
–25 to 80°C (–40 to 176°F) for EJ120
–40 to 10C (–40 to 212°F) for EJ310
L capsule
Ambient Humidity Limits
0 to 100% RH
Working Pressure Limits (Silicone oil)
EJ120 -50 to 50 kPa
Maximum Pressure Limits
EJX110A
Capsule Pressure
F, L 16 MPa (2300 psi)
M, H, V 25 MPa (3600 psi)*
* 16 MPa for wetted parts material code H, M, T, A, D,
and B.
EJA110E
Capsule Pressure
F, L, M, H, V 16 MPa (2300 psi)*
* 25 MPa (3600 psi) when /HG is specied.
EJ130
Capsule Pressure
M, H 32 MPa (4500 psi)
EJ310
Capsule Pressure
L 10 kPa abs (2.95 inHg abs)
M 130 kPa abs (38 inHg abs)
A 3.5 MPa abs (500 psia)
B 16 MPa abs (2300 psia)
EJ430
Capsule Pressure
H 500 kPa (2000 inH2O)
A 3.5 MPa (500 psi)
B 16 MPa (2300 psi)
EJ440
Capsule Pressure
C 32 MPa (4500 psi)
D 50 MPa (7200 psi)
Minimum Pressure Limit
See graph below
EJ110, EJ130, EJ430, EJ440
Atmospheric
pressure
-40
(-40)
0
(32)
40
(104)
80
(176)
120
(248)
1(0.14)
2.7(0.38)
10(1.4)
(psi abs)
100(14.5)
Process temperature °C (°F)
Working
pressure
kPa abs
Applicable range
F0901.ai
EJ310
-40
(-40)
0
(32)
40
(104)
80
(176)
120 (248)
0.1(0.75)
0.13(1)
1(7.5)
100(750)
10(75)
2.7(20)
0.46
(3.45)
0.01(0.075)
0.013(0.1)
85
(185)
(mmHg abs)
Working
pressure
kPa abs
Applicable range
Process temperature °C (°F)
M,A and B capsule
L capsule
F0902.ai
Figure 9.1 Working Pressure and Process
Temperature