User’sManualDaqstation DX1000/DX1000N/DX2000 and DAQSTANDARD Functional Changes Resulting from the Updating(Applies to DX1000/DX1000N/DX2000 with hard
10IM 04L41B01-03EResetting the Computed Value during Computation (/M1 and /PM1 Options)You can reset the computed value not only when the computation
11IM 04L41B01-03ESorting the Files by the Update Date/TimeThe files can be sorted in order by the update date/time in the screens below. This function
12IM 04L41B01-03EStorage Method for Constantly Retaining the Most Recent Data Files in the CF Card (Media FIFO)When saving the data files automaticall
13IM 04L41B01-03EStatus Display of the CF Card• If an error occurs on the CF card, the CF card icon in the status display section changes to an error
14IM 04L41B01-03EProgress Display When Saving All Data of the Internal MemoryIf you carry out All Save* on the memory summary screen, a pop-up window
15IM 04L41B01-03EFunction for Automatically Assigning MW100s to the Modbus Client (DX2000 Only)If the DX2000 is a Modbus client, MW100s, Modbus server
16IM 04L41B01-03ESetup ItemsThe MW100 channels are assigned to the external input channels of the DX as follows:• Channel Number The channels of the
17IM 04L41B01-03ENoteAbout the MW100• MW100s that support auto setting are those with firmware version R2.22 or later.• MW100 modules that can be au
18IM 04L41B01-03EChanging of the Default Setting of the Web Server FunctionThe default setting of the Web server function has been changed to Use. You
19IM 04L41B01-03ECommunication CommandsCommunication commands are described in chapter 3, “Commands” in the DX1000/DX1000N/DX2000 Communication Interf
2IM 04L41B01-03EContentsOverview of the Functional Changes ...
20IM 04L41B01-03EAlarm Output Relay Action When the Alarm ACK Operation Is ExecutedWO Set alarm and DO settingsSet the Output RelaySyntax WO p1,p2
21IM 04L41B01-03EDAQSTANDARD for DXAdvancedThe functions below have been added or changed since DAQSTANDARD revision 7.21.Hardware ConfiguratorSetup M
22IM 04L41B01-03EDialog Box for Setting the Display Type for Each View GroupSelect [View group] on the [General Setting] tab screen.Double-click the v
23IM 04L41B01-03EViewerLinking the Previous and Subsequent Files CollectivelyYou can collectively link previous and subsequent files to the working fi
3IM 04L41B01-03EThank you for purchasing the Daqstation DX1000/DX1000N/DX2000 (DX). This manual covers functions that has been changed in hardware sty
4IM 04L41B01-03EOverview of the Functional ChangesBelow is an overview of the main functional changes.• Improvement to the Operability on the Histori
5IM 04L41B01-03EOperations on the DX1000/DX1000N/DX2000Below are the operational changes as a result of the functional changes. This section mainly us
6IM 04L41B01-03EImprovement to the Display Group Setup OperationThe channel settings of a display group can be copied to another group.Setup ScreenPre
7IM 04L41B01-03ESetup Items• Bar graph > Base position Set the base position of the bar graphs to Normal, Center, Lower, or Upper. The bar graphs
8IM 04L41B01-03E When the Display Direction of the Bar Graph Is Horizontal The span lower limit (or scale lower limit) becomes the left edge of the
9IM 04L41B01-03EAlarm Output Relay Action When the Alarm ACK Operation Is ExecutedYou can select the relay output status that is enabled after the ala
Comments to this Manuals