<14. EXPLOSION PROTECTED TYPE INSTRUMENT>
14-10
IM 01F06A00-01EN
(Integral Type Vortex Flowmeter and Remote Type
Vortex Flow Detector)
Temperature Code
Ambient
Temperature
Process
Temperature
T4 60°C 135°C
T3 60°C 200°C
T2 60°C 300°C
T1 60°C 450°C
Temperature Code: T4 (Remote Type Vortex Flow
Converter)
Ambient Temperature: -40 to 60°C
Enclosure: Type 4X
Electrical Parameters: Vmax=30Vdc,
Imax=165mAdc,Pmax=0.9W,
Ci=12nF, Li=0.15mH
(2) Wiring
• Explosion proof
WARNING
All wiring shall comply with Canadian
Electrical Code Part I and Local Electrical
Codes.
In Hazardous locations, wiring shall be in
conduit as shown in the gure.
A SEAL SHALL BE INSTALLED WITHIN
50cm OF THE ENCLOSURE.
When the equipment is installed in Division
2, “FACTORY SEALED, CONDUIT SEAL
NOT REQUIRED”.
(3) Operation
• Explosion proof
WARNING
Note a warning label worded as follows.
Warning: OPEN CIRCUIT BEFORE
REMOVING COVER.
Take care not to generate mechanical
spark when access to the instrument and
peripheral devices in hazardous locations.
(4) Maintenance and Repair
WARNING
The instrument modi cation or part
replacements by other than authorized
representatives of Yokogawa Electric
Corporation are prohibited and will void CSA
Certi cation.